LIGHT MICROSCOPES-
Inverted/upright laser scanning confocal, widefield
epifluorescence with
structured illumination (Apotome) and digital deconvolution, digital
and film cameras, 3D reconstruction and extended focus, standard
and inverted microscopes, DIC and phase contrast, halogen
epi-illumination, Iatia Phase Reconstruction, Macroscope,
Polarising Microscope
TRANSMISSION
ELECTRON MICROSCOPES
Hitachi
H7100FA (125kV TEM, 1995) with digital camera
Used
for general and cold stage work not requiring high tilt.
Side-entry (limited)tilt stage. Fine probe capability (20-100nm) 0.144
nm lattice resolution. Double diffusion pump vacuum system. Electronic
image rotation. Standard single-tilt, double-tilt and high resolution
diffraction/reflection specimen holders. W or LaB6 cathode. 22 plate
large format camera. Specimen movement trace. Point-to-point
measurement. PC Interface. LN2 Cold Stage (Oxford Instruments). Gatan
622SC CCD TV camera with image intensifier. VCR. SIS Megaview III
Widefield CCD camera (1300 x 1024 pixel, 12 bit).
Philips EM430 with digital
camera (300kV TEM/STEM, bought 1985, transferred to ANUEMU and upgraded
1998)
Used for materials science or
biological work requiring higher resolution, high tilt/high kV or X-ray
analysis
Side-entry high-tilt stage. Diffusion/ion pump system. LaB6 or
tungsten. Wide range of specimen holders including double tilt, hot and
cold stages. Low dose unit. Ultra-thin window Oxford ISIS EDXA with
mapping. Direct and annular STEM, digitised through ISIS. TVIPS 1024 x
1024 24µm 12 bit CCD camera and image processing system. 36
plate large format sheet film camera.
Philips CM300 with digital
camera (300kV TEM. 1999)
Sited
in RSES. Gatan 1024 x 1024
CCD camera, EDAX EDXA. Contact Dr John Fitz Gerald (John.Fitzgerald@anu.edu.au)
or phone (02) 6125 4176.
SCANNING ELECTRON MICROSCOPES
Cambridge S360
(SEM, 1987)
Used for general purpose SE
and BSE imaging, cryoSEM and X-ray analysis.
LaB6, Tracor Northern EDXA detector (Be window, 147eV) with Moran EDXA
processing system, 4-segment backscatter detector, Oxford CT1500B
Cryotrans cold stage/coating unit , point-to point measurement
intrinsic to microscope. Turbomolecular and sputter ion pumps,. 70mm
("220") roll film, videographic printer, ImageSlave 1024
x 768 slow-scan image acquisition.
JEOL JSM6400 (SEM, 1990)
Oxford
ISIS EDXA with ATW window (sensitive down to boron), quantitative and
qualitative elemental mapping, CAMEO " chemical imaging" system.
Robinson
backscatter detector, forescatter detector, transmitted electron
detector, LaB6 or tungsten filament. Diffusion and sputter ion pumps,
70mm roll film, videographic printer, video output, ImageSlave 1024 x
768 slow-scan image acquisition to networked PC.
Hitachi S2250-N (Conventional
and low-vacuum SEM, 1992)
Sited in RSES. Used mainly for
cathodoluminescence imaging, May also be available for uncoated/unfixed
specimens, tensile stages etc. (Contact access through ANUEMU).
Tungsten
filament, diffusion pump. Gas pressure in VP mode up to 2 torr air,
allows viewing uncoated specimens. Secondary (E-T) and Robinson
backscatter/SE detectors. Framestore, video output.
(Not currently in use- Fullam Peltier-cooled stage, manipulators,
tensile/compression stages, absorbed electron detector, beam blanking
unit). ImageSlave slow-scan image acquisition (1024 x 853) .
Cathodoluminescence - panchromatic imaging (off-axis mirror and
PMT) installed and spectrographic (fibre optic and Ocean Optics
CCD spectrometer) available.
Hitachi S4500 (Cold Field
Emission SEM, 1996)
High
resolution, low kV, "semi in-lens" design. 0.5 to 30kV. Diffusion/ion
pump cascade system. "Upper and lower" secondary electron detectors,
Robinson Mk 6 backscatter detector, Oxford high resolution cold stage
with magnetron sputter coater, ImageSlave slow-scan image acquisition
(1024 x 768). 70mm roll film camera, video output etc.
Hitachi 4300 SE/N
(Schottky Field Emission SEM, 2006)
Analytical
below-lens design VP to 1000Pa. SE, YAG BSE and gaseous SE detector
(biassed absorbed current type). Fitted with Oxford Instruments cold
stage and INCA Energy 350 EDXA system. HKL EBSP, Robinson CL, 2-axis
motorised stage. IR Camera.
Zeiss UltraPlus analytical FESEM (2008)
1.8nm resolution at 1 kV. Angular
sensitive Backsactter (AsB), Energy sensitive Backscatter (EsB), Upper
an lower SE detectors, gas injection needle for charge compensation. Fitted with Oxford
Instruments cold
stage and INCA Energy 450 EDXA system plus Oxford HKL EBSP,
5-axis
motorised stage. IR Chamber scope.
LIGHT MICROSCOPES
Leica laser
scanning confocal microscope. inc. uv laser. Inverted and
(2004) upright microscopes sharing scan head.
Zeiss Axioplan 2 (2003) Fully
motorised upright epifluorescence microscope with Apotome deconvolution
system, digital deconvolution and 3D reconstruction software
(Axiovision suite). Zeiss MRc 12 bit mono camera
Zeiss Axioskop with
35mm film, video, and SPOT CCD (1300 x 1240, 36 bit colour) cameras.
Halogen trans and epi-illumination, DIC(polarising), Optovar, rotating
stage.
Nikon Optiphot
epi-fluoro, (phase and epi-fluoro objective turrets) with SPOT
Insight 1600 x 1200 mono 12 bit camera, Iatia QPm
Quantitative Phase System. Sony 3-chip video camera
Wild M400 photomacroscope
with SPOT FLEX CCD camera 14bit 50Mb colour CCD camera.
Upgraded with LEICA illumination base.
Nikon inverted microscope
Leitz Polarising microscope
2 Nikon Labophots, one with
phase contrast, halogen trans and epi-illumination. 5 to 100x objectives
Small "dissecting" stereo-microscopes
Wild stereo-microscope
with observer tube
Videoflex Macro video
camera
Video output
from microscopes and Videoflex,, linked to videorecorder, image
analysis PC, videoprinter.
Spectrometer adapter available for light microscopes.
IMAGE PROCESSING
Image and
data analysis, Digitising/measurement systems, 3-D reconstruction,
Image Processing and Printing.
The"Fishbowl",
Rm 035, contains light microscopes and , PCs with image handling
software and a variety of input and output devices including a high resoluton Epson flatbed
scanner with transparency option, and a large digitising
tablet. It is also used for processing digital images taken
directly from the electron microscopes. Equipment in this area is
continually being upgraded, so check to see what is available from time
to time.
SOFTWARE
For PCs : (4 stations)
Various options for image presentation, 2D analysis, deconvolution and
3D reconstruction including AnalySIS, Image Pro, ImageJ,
IrfanView, ImageJ, Offline Leica confocal software,
Zeiss Axiovision, .Adobe Photoshop, Sigma-Scan Pro, Surfdriver
(3-D recon). Lucis image processing,
OUTPUT DEVICES
Network
access to 1200 dpi. postscript laser printers. In general colour and
photoquality printing is not supported by the EMU. Most PCs are
networked, and have CD-RW, and DVD drives. BYO USB drives
are recommended.
ULTRAMICROTOMES
5 Reichert
Ultracuts, two with cryo-sectioning attachments. Staining area
CRYO- EQUIPMENT
LN2 Cold stages on 2 SEMs and
3 TEMS
High
Pressure Freezer
Leica EM-PACT. Pressure controllable to 2300 bar. Specimen
holders currently 350 micron x 17mm tubes, or c. 2mm dia x 200 micron
deep larger flat holders.
Leica Freeze-substitution
..programmable
Cryopliers
Propane Jet Freezer Bal-Tec
JFD 030 Twin jet freezer
"Controlled Environment Vitrification
System" For fast plunging into liquid ethane or propane,
particularly for TEM grids
Freeze-fracture Balzers 301
with turbomolecular pump, electron beam evaporation guns, double
replica device
Freeze-drying Routine -
Dynavac with Peltier-cooled stage, rotary pump
Freeze drying Small
sample/High-resolution- Polaron E7480, LN2 cooled with sputter and
evaporative coating units, diffusion pump.
OTHER
FACILITIES
Sputter Coater (high res) Pt or AU,
Bio-Rad
Sputter Coater (Au/Pd): Emitech
Evaporative
Coater Dynavac CS300, diffusion pumped
Glow
Discharge Unit: Emitech. Reversible polarity, gas
Critical
point dryer Balzers
Ocean Optics portable optic
fibre spectrometer
Pelco BioWave Microwave Fixation Oven. 80w
to 750w, vacuum chamber, temperature restriction, programmable
Biological
Specimen Processing A number of fixatives, buffers,
resins etc are available as stock. A dissecting microscope is available
for use within the fumehood. Before using
this area, see staff for explanation of features and safety procedures.
Polishing
/ Grinding area. Setting up- wheel with abrasive paper,
cloths and paste
Fumehoods,
ultrasonic bath, bench microfuge, ovens, forceps sharpening kit, stereo
viewers, balances, shaker, VCRs.
|